Authors: Ciara A. Kerney, Kirsten Hodges, ASA and Jeffrey Doyle, ASA
WHAT IS MAGNETIC RESONANCE IMAGING (“MRI”)?
Magnetic resonance imaging (i.e., MRI) is a non-invasive medical imaging technique used to produce comprehensive anatomical images utilizing a magnetic field and computer-generated radio waves. MRI scans can generate detailed images of nearly all internal anatomical structures, including bones, muscles, organs, soft tissues, and blood vessels. Today, MRIs are deployed by healthcare providers throughout the patient care cycle, beginning with disease detection and continuing with ongoing patient monitoring after treatment. Unlike x-ray technology, MRI machines do not produce radiation and, therefore, are often the preferred test of choice for patients requiring frequent imaging.
HISTORY OF MRI MACHINES
Prior to the development of magnetic resonance imaging came nuclear magnetic resonance (“NMR”). NMR was developed in 1937 by Columbia University physics professor Isidor Rabi as a method of measuring the movement of atomic nuclei in the study of chemical substances. Building upon Rabi’s work, American physician Raymond Damadian concluded that cancerous cells contained more water than healthy cells. Dr. Damadian posited that cancer cells could be detected by scanners that immersed a part of the human body in radio waves and subsequently measured the emissions from hydrogen atoms. Based on his theory, Damadian went to work building a human-sized scanner to further test this approach.
As Dr. Damadian proceeded with his work, chemist Paul Lauterbur, who had found a way to use NMR technology to create images, applied knowledge from his own work to human anatomy. Lauterbur realized that a gradient magnetic field allowing observers to take two-dimensional images of an object could potentially be utilized to create three-dimensional images. Lauterbur went on to create the first magnetic resonance image – one of two water-filled test tubes – in 1971. Meanwhile, the work of physicist Peter Mansfield led to the first successful human anatomical scan utilizing a new “line scan imaging” technique using NMR.
In 1977, Damadian, credited as the first physician to leverage NMR technology, ultimately created the first whole-body human scanner, which was dubbed the Indomitable. Damadian founded an MRI manufacturing company called FONAR Corporation in 1978, and FONAR brought the first commercial MRI scanners to market in 1980. Damadian’s device was approved by The Food and Drug Administration (“FDA”) in 1984 and coverage of MRI scans under Medicare was approved in 1985. Peter Mansfield went on to develop the echo-planar imaging technique, a technique using a single nuclear spin excitation per image and still utilized today to reduce MRI scan times. With the scientific contributions of Damadian, Lauterbur, and Mansfield, MRI machines became widely available in the 1980’s and persist as one of the most prevalent diagnostic tools in medicine.
CURRENT TECHNOLOGY AND LEADING MANUFACTURERS
MRI machines can come in various forms (e.g., open bore, upright, mobile), and are often differentiated by their magnetic field strength. A tesla – denoted as “T” – is the unit of measurement used to define the strength of a magnetic field such as that seen in MRI scanners. The healthcare industry currently utilizes MRI machines ranging from 0.55T up to 7.0T. While 1.0T, 1.5T, and 3.0T scanners are fairly common across the industry, lower tesla machines (i.e., 0.55T) are often used within the clinical workflows of specialties like pulmonology and medical cardiology, and higher tesla machines (i.e., 7.0T) are currently utilized in highly specialized work, including clinical and research-based neurology.
One of the lowest tesla MRI machines currently available on the market is the Siemens Healthineers 0.55T MAGNETOM Free.Max. The MAGNETOM Free.Max received approval from the FDA in July 2021 and positioned itself to break barriers as one of the smallest and most lightweight options with the largest bore (i.e., the circular patient opening) on the market. With its smaller size, quieter operation, and infrastructure lite nature, the MAGNETOM Free.Max has opened the doors to explore new clinical siting opportunities for MRI machines, and allows for the use of whole-body MRI scanning in outpatient centers, emergency rooms, and intensive care units.
The Philips Ingenia Ambition 1.5T is one of three of Philips Healthcare’s current 1.5T MRI offerings. While MRI machines have historically required liquid helium to cool their superconductive magnet coils, the Ingenia Ambition 1.5T recently emerged as the first helium-free MRI. The technological advances inherent within a helium-free system promise more predictable operations and greater efficiencies without the potential for helium related complications or concerns of reliance on a non-renewable resource.
With initial approval of the first 7.0T MRI in 2017, GE HealthCare’s SIGNA™ 7.0T is now one of many 7.0T MRI scanners available on the commercial market. These powerful MRI scanners are utilized by healthcare professionals in advanced clinical and research settings for highly technical neurological and musculoskeletal imaging. The advanced imaging produced by 7.0T scanners is commonly utilized by researchers in the study of neurodegenerative diseases, such as Parkinson’s disease, to visualize alterations in the neurological field of view.
FUTURE TECHNOLOGY
Perhaps the greatest breakthrough in MRI technology in recent years was the introduction of the Magnetic Resonance Imaging Guided Linear Accelerator (the “MRI-LINAC”). As discussed in HealthCare Appraisers’ publication, a linear accelerator (“LINAC”) is a technically advanced medical system utilized in the delivery of radiation treatment for cancer patients. Combining the treatment capabilities of a LINAC with the imaging capabilities of an MRI machine allows for the delivery of highly personalized treatment plans which can be monitored and adjusted in real time. The MRI-LINAC enables healthcare professionals to ensure greater accuracy in the deployment of radiation treatment by detecting even the smallest shifts in internal anatomical positioning and adjusting accordingly. The increased accuracy afforded by the MRI-LINAC reduces radiation exposure to surrounding healthy tissues and organs and limits the risk of unanticipated and adverse outcomes related to treatment. ViewRay Technologies, Inc.’s MRIdian® received FDA approval in 2017 and became the world’s first MRI-LINAC. Today, ViewRay’s MRIdian®, equipped with a 0.35T MRI, finds itself in competition with the 1.5T Elekta Unity.
APPRAISAL CONSIDERATIONS
Normal Useful Life (“NUL”) – The NUL considered for an MRI machine under a cost approach to value is estimated to be 10 years. Within a cost approach, an appraiser must consider the maintenance history of the subject machine and assign consideration to software and/or hardware overhauls and updates. While such updates can be costly, they can significantly extend the NUL of an MRI machine. Due to the frequency of the aforementioned upgrades, it is not uncommon to see MRIs in the field well beyond a NUL of 10 years.
CONCLUSION
MRI machines have transformed disease detection, diagnosis, treatment, and patient monitoring in the healthcare space. Comprehensive knowledge of MRI-specific features such as MRI magnet strength and software capabilities is required to appraise MRI machines. As the value of an MRI machine can be heavily dependent upon the special considerations discussed herein, it is necessary to engage a qualified and knowledgeable expert in medical equipment valuation. Healthcare Appraisers has provided valuations of MRI equipment nationwide, and has extensive experience in the valuation of MRI machines across the spectrum.
Read the other articles in our Insights on Imaging series:
[1] Defined by the American Society of Appraisers as “a form of depreciation in which the loss in value is due to factors inherent in the property itself and changes in design, materials, or process that result in inadequacy, overcapacity, excess construction, lack of functional utility, excess operating costs, etc.”
[2] Defined by the American Society of Appraisers as “a form of depreciation or loss in value caused by unfavorable external conditions.”
[3] Centers for Medicare & Medicaid Services: Section 135(a) of the Medicare Improvements for Patients and Providers Act of 2008 (MIPPA) (P.L. 110- 275) amended section 1834(e) of the Social Security Act (the Act).